Structural Specifications
for a
10' x 40' Staff Quarters




ROOF (Exterior to Interior)
  • E.P.D.M. (one piece rubber membrane roof)
  • E.P.D.M. (one piece rubber membrane roof)
  • 7/16" Oriented strand board (O.S.B.)
  • 2 x 8 - 16" O.C. rafters
  • R20 insulation
  • 6 mil vapour barrier
  • 7/16" oriented strand board
  • ½" vinyl covered gyproc (Adobe White)

  • WALLS (Exterior to Interior)
  • 7/16" Smart Panel (25 year manufacturers warranty) siding - 12" with colour accented trim
  • Optional Mesa S-Lock tin exterior panels
  • 2x4 - 16" O.C. studs
  • R12 insulation
  • 6 mil vapour barrier
  • 7/16" O.S.B. (backing)
  • ½" vinyl covered gyproc (Irish Linen)
  • Marquis Oak finish ( baseboard & trim )

  • FLOORS (Exterior to Interior)
  • Twin 8" Steel I-Beam skid bolted on floor joists during manufacturing (Optional)
  • 3/8" Sturdywood plywood (exterior grade)
  • 2x8 - 16" O.C. joists
  • R20 insulation
  • 3/4" tongue and groove - good one side plywood
  • Heavy duty (35MM wear) vinyl flooring

  • WINDOWS AND DOORS
  • 4 - 36" x 36" double glazed Aluminum sliders (PVC optional)
  • 1- 34" x 80" solid core metal door

  • MECHANICAL & ELECTRICAL
  • 100 amp service panel with power cord (30')
  • 5 GFI receptacles
  • centre row of dual flourscent lighting
  • electrical baseboard heat
  • Propane, forced air, A/C - compatable (optional)

  • FRAME / WHEELS
  • 8" steel channel frame
  • heavy duty (pintle) tow hitch and jack leg
  • tandem axle (electric brakes on both)
  • 12 ply tires
  • three (3) step steel entrance stair and mounting brackets

  • OPTIONS

     

     