Structural Specifications
for a
12' x 40' Office




ROOF (Exterior to Interior)
  • E.P.D.M. (One piece rubber membrane roof)
  • 7/16" Oriented strand board (O.S.B.)
  • 2 x 8 - 16" O.C. rafters
  • R20 insulation
  • 6 mil vapour barrier
  • 7/16" oriented strand board
  • ½" vinyl covered gyproc (Adobe White)

  • WALLS (Exterior to Interior)
  • 7/16" Smart Panel (25 year manufacturers warranty) siding - 8" with colour accented trim
  • 2x4 - 16" O.C. studs
  • R12 insulation
  • 6 mil vapour barrier
  • 7/16" oriented strand board
  • ½" vinyl covered gyproc (Irish Linen)

  • FLOORS (Exterior to Interior)
  • Twin 8" Steel I-Beam skid bolted on floor joists during manufacturing.
  • 3/8" plywood (exterior grade)
  • 2x8 - 16" O.C. joists
  • R20 insulation (2x8)
  • 3/4" tongue and groove - good one side plywood
  • Heavy duty (35MM wear) vinyl flooring

  • WINDOWS AND DOORS
  • 5 - 36" x 36" double glazed Aluminium sliders (PVC optional)
  • 2- 34" x 80" solid core metal door

  • MECHANICAL & ELECTRICAL
  • 150 amp service panel with power cord (30')
  • 8 duplex receptacles
  • Centre row of dual fluorescent lighting
  • Electrical baseboard heat

  • FRAME / WHEELS